- Measurement Accuracy: ±1,0 % ill, ±2,0 °C
- Analog output: J hőelem, 0 ... 10 V, 0 ... 1 V, K hőelem
- Explosion safety: -
- Options/Configurations: USB, RS485, RS232, Profibus DP, Ethernet, CAN
- Design: külön elektronika-egység
- Measurement range (max.): 975 °C
- Sensor temperature: -40 … 180 °C
- Spectral Range: 8 x 14 µm
- Electronics dimension: 98 x 70 x 30 mm
- Measurement range (min.): -50 °C
- Time constant: 6 ms
- Electrical supply: 8 ... 36 V DC, 8 ... 36 V DC
- Alarm output: 24 V / 50 mA (open collector)
- Industrial protection: IP65
- Optics (ratio): 25:1
- Sensor size: M12 x 1 x 28 mm
- Smallest measuring spot: SF: 6,5 mm közvetlen optika előtt, CF: 0,6 mm 10 mm távolságban